Smart Air Circuit Breaker
The product uses the small circuit breaker as the main body, and is developed by upgrading the actuator and adding some electronic components,with the maximum current of 125A, and the breaking frequency of 10,000 times.It can conduct the comprehensive monitoring for relevant parameters of power distribution systems, with power monitoring, energy consumption monitoring, electrical fire monitoring, electric energy biling/charging,fire monitoring,and other functions,widely applied in energy management systems, distribution automation systems,intelligent buildings,mobile base stations,inteligent switch cabinets,etc.
信息资料

OVERVIEW

The produet uses the small circuit breaker as the main bodyand is developed by upgrading the actuator and adding someelectronic components, with the maximum current of 125A, andthe breaking frequency of 10,000 times. It can conduct thecomprehensive monitoring for relevant parameters of powerdisitribution systems, with power monitonng, energy consumptionmonitoring,electrical fire monitoring,electric energybillingicharging,fire monitoring,and cther functicns, widelyapplied in energy management syslems, distribution aulcmationsystems,intelligent buildings, mobile base stations, intelligantswitch cabinets. etc.


FEATURES

1.Have the complete information monitoring function, ableto carry out real-time monitoring for electric current,voltage,residual curent,cable temperature and otherinformation.

2.0wn the complete safety protection function, andimmedialely take protective actions in case of electricleakage,overaltage,voltage shortage,short circuit,overioad and overtemperature in the lne. Have functions,such as lightning surge protection and automaticreclosing.

3. Perfectly connect the smart power platform: detect anduplcad real-time dala on active pover, reactive poer,apparent power. power factor, irequency, active funclion,and reactive function.

Main technical parameters

Un

V

3P+N/4P 400V AC/50Hz 1P+N/2P 230V AC/50Hz

Rated current

A

125A

Circuit breaker breaking capacity


≥6KA

Wiring method

KA

3P+N/4P Three-phase four-wire system1P+N/2PSingle-phase

485Communication

 


StandardRS485Communication interface, compliantDL/TThe "Communication Protocol for Residual Current Operated Circuit Breakers" requires

Temperature protection

 


Busbar temperature detection: When abnormal temperature of any phase is detected, the switch trips (default temperature protection value)80°C(Can be set remotely)

External dimensions

 


Two poles:90mm×125×78mm Four Poles:126mm×125mm×78mm(Width × Length × height)